Case SR175, SV185 SkidSteer Service Manual
$36.00
Case SR175, SV185 SkidSteer Service Manual – 1670 Pages
Case SR175, SV185 SkidSteer Service Manual – 1573 Pages
Publication Number: Part number 47711658 & 47851947
1st edition
English
May 2014 & May 2015
Format: PDF
- Description
- Reviews (0)
Description
Case SR175, SV185 SkidSteer Manual
SkidSteer Model: SR175, SV185
Publication Number: Part number 47711658 & 47851947
1st edition
English
May 2014 & May 2015
Format: PDF
Case SR175, SV185 SkidSteer Service Manual – 1670 Pages
Case SR175, SV185 SkidSteer Service Manual – 1573 Pages
SR175:
PIN NEM465956 and above
PIN NDM465633
SV185:
PIN NEM466759 and above
PIN NDM466611 and above
Manual Table of Content:
- Contents
- Introduction
- Engine
- Front Axle System
- Rear Axle System
- Hydrostatic Drive
- Brakes and Controls
- Hydraulic Systems
- Frames and Ballasting
- Wheels
- Cab Climate Control
- Electrical System
- Front Loader and Bucket
- Plateform, Cab, Bodywork and Decals
- Specials Tool Index
Manual Extract: Pump – Troubleshooting
Problem | Possible Cause | Correction |
One Transmission (Right or Left) Works Correctly and the Other Does Not |
1.If you have a EH unit perform EH pump electrical check and verify that unit has been properly calibrated. Check the interlock valve power/function. |
A. Is there still a problem? No: Troubleshooting complete. Yes: Go to Step 2. |
 | 2. Check the brake valve power/function. Make sure park brakes are released. |
Is there still a problem? No: Troubleshooting complete. Yes: Go to Step 3. |
 | 3. Check the pressure setting of the circuit relief valve for the transmission with the problem. | Do – Check the Circuit Relief Valve Pressure. Is there still a problem? No: Troubleshooting complete. Yes: Go to Step 4. |
 | 4. Check the charge pressure. | Is there still a problem? No: Troubleshooting complete. Yes: Go to Step 2. |
Machine does not have enough power |
1. . If you have a EH unit perform EH pump electrical check and verify that unit has been properly calibrated. Check the interlock valve power/function. |
Do – Check the Charge Pressure/Flow. |
 | 2. Full throttle engine speed is OK, rated engine speed is low. |
A. Problem in engine or fuel system. Repair as required. B. Is there still a problem? No: Troubleshooting complete. Yes: Go to Step 3. |
 | 3. Check charge pressure. | Refer to Pump and motor components – Pressure test (29.218) to determine if the pump or drive motor(s) have failed. |