Komatsu D85EXi-18, D85PXi-18 Dozer Service Manual
$36.00
Manual Included:
- Shop Manual: 3136 pages
- Operation and Maintenance Manual: 217 pages
Specifications:
- Brand: Komatsu
- Model: D85EXi-18, D85PXi-18
- Type: Dozer
- Serial Number: 22083 and up
- Manuals: Shop Manual and Operation and Maintenance Manual
- Publication Numbers: SEN06576-01 and TEN00712-02
- Language: English
- Format: PDF
- Description
- Reviews (0)
Description
Table of Contents
- Index and foreword
- Specification
- Structure, function and maintenance standard
- Standard value table
- Testing and adjusting
- Troubleshooting
- Disassembly and assembly
- Maintenance Standard
- Appendix
- Circuit Diagrams
- Index
Proper service and repair are extremely important for safe machine operation. The service and repair techniques recommended by Komatsu and described in this manual are both effective and safe. Some of these techniques require the use of tools specially designed by Komatsu for the specific purpose.
FAILURE CODE [879BKA] A/C Fresh Air Temperature Sensor Open Circuit | |
Details of failure |
Air conditioner controller detects open circuit in outside air temperature sensor. |
Action of controller |
Air conditioner controller transmits open circuit information of outside air temperature sensor to machine monitor by CAN communication. Ignores data of outside air temperature sensor and continues control of air conditioner in automatic air conditioner mode. |
Phenomenon on machine |
Since air conditioner outside air temperature sensor has open circuit, outside air temperature is not considered in automatic air conditioner mode. (Air conditioner is not affected in manual mode.) |
Related information |
โข After repairing, check if the failure code is cleared by the following procedure. Procedure: Turn starting switch to ON position. โข Check if this failure code is displayed on electrical system failure record screen in service mode of machine monitor. โข For each connector, see โInstallation locations of air conditioner parts and arrangement of connectorsโ. โข Since air conditioner controller connector ACECU has no T-adapter and has small pins, perform troubleshooting by using intermediate connector (although intermediate connector has no T-adapter either, it has large pins). โข When replacing air conditioner harness between air conditioner controller connector ACECU and intermediate connector, replace air conditioner unit. |