Case 370, 420, 470, 500, 540, 580, 620 Steiger Tractor Service Manual

$45.00

Case 370, 420, 470, 500, 540, 580, 620, 540, 580, 620 Steiger Tractor Service Manual:
1. Serial/PIN Starting with ZEF300001 and ZEF308000
Service Manual: 5569 Pages

2. Serial/PIN Starting with PIN ZFF308001 and above
Service Manual: 6287 Pages

3. Serial/PIN Starting with JEEZ00000FF314001 and above

Service Manual: 7040 Pages

Add a note during checkout which Serial/Pin Number Variant of the Manual you need when ordering

Categories: ,
View cart

Description

Case 370, 420, 470, 500, 540, 580, 620 Steiger Tractor Manual

Steiger Tractor Model: 370, 420, 470, 500, 540, 580, 620

Publication Number: 47680525 & 48193194 & 47924539
1st edition
English
October 2017
Format: PDF

Add a note during checkout which Serial/Pin Number Variant of the Manual you need when ordering

Case 370, 420, 470, 500, 540, 580, 620, 540, 580, 620 Steiger Tractor Service Manual:
1. Serial/PIN Starting with ZEF300001 and ZEF308000
Service Manual: 5569 Pages

2. Serial/PIN Starting with PIN ZFF308001 and above
Service Manual: 6287 Pages

3. Serial/PIN Starting with JEEZ00000FF314001 and above

Service Manual: 7040 Pages

Manual Table of Content:

  • Contents
  • Introduction
  • Engine
  • Power Coupling
  • Transmission
  • Four Wheel Drive (4WD) System
  • Rear Axle System
  • Power Take Off (PTO)
  • Brakes and Controls
  • Hydraulic System
  • Hitches, drawbars and implement couplings
  • Frames and ballasting
  • Steering
  • Wheels
  • Tracks and Track Suspension
  • Cab Climate Control
  • Electrical Systems
  • Plateform, Cab, bodywork and decals
  • Special Tool Index
  • Hydraulic Schematic
  • Electrical Schematic

Manual Extract: Charge pump – Pressure test – Charge pressure test

Perform this test when experiencing problems with all the PFC circuits, all remote sections or the hitch system are not operating normally. The symptoms could be low flow, aerated oil or unusually loud pump operation possibly due to cavitation.
1. Install both articulation cylinder locking blocks before performing any tests.

2. Place cardboard in front of the oil cooler to help heat the oil. Install a load loop into a remote section to aid in heating up system. Start the tractor and run at 1000 RPM until the hydraulic oil reaches a minimum of 50 °C (120 °F). Remove the cardboard from in front of the oil cooler.

3. Install a 7 bar (100 psi) pressure gauge to the charge pressure diagnostic port located inside the right hand service door.
Increase engine speed to 2000 RPM. Charge pressure should be minimum 2 bar (30 psi) at 2000 RPM.
If charge pressure is low this may indicate that the charge pump is losing efficiency and may need replacement.
When complete, remove both articulation cylinder locking blocks.

 